Sign In | Join Free | My jazzonln.com
jazzonln.com
Products
Search by Category
Home > Flanges >

Cooling Type Water Cooled Perkins Diesel Generators 2000KW 4-Stroke

Categories Perkins Diesel Generators
Brand Name: HIDIER-Perkins
Model Number: HDP2000/S
Certification: CE, CSA, NOISE, GS, EC-II, EPA, CARB, GOST.
Place of Origin: Perkins Engine, assembled in China
MOQ: 1pcs
Payment Terms: T/T, L/C
Supply Ability: 1000pcs/week
Delivery Time: Within 30 days
Packaging Details: Plywood box
Output Capacity: 2250/2475kVA
Output Power: 2000/2200kW
Genset Type: Hidier
Engine: Perkins
Frequency: 50Hz / 60Hz
Cooling Type: water cooled
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Cooling Type Water Cooled Perkins Diesel Generators 2000KW 4-Stroke

    Cooling Type Water Cooled Perkins Diesel Generators 2000KW 4-Stroke


    HDP Series HDP2000/ HDP2000S

    Model

    Standby Power

    Prime Power

    Engine

    Alternator

    Control Panel

    KVA

    KW

    KVA

    KW

    Stamford

    Hidier(Optional)

    Model

    HDP2000/S

    2475

    1980

    2250

    1800

    4016-61TRG3

    PI734G

    HD1800

    MRS10

    Spec #1.1 Features

    1

    Excitation system: self-excited (AREP and PMG are optional)

    2

    ATS (automatic transfer switch) receptacle

    3

    Lockable battery isolator switch

    4

    Stainless galvanized zinc plates with strong corrosion resistance

    5

    Vibration isolators between the engine/alternator and base frame

    6

    Integrated wiring design

    7

    Base fuel tank for at least 8 hours running

    8

    Equipped with an industrial muffler

    9

    50℃ radiator

    10

    Top lifting and steel base frame with forklift holes

    11

    Drainage for fuel tank

    12

    Complete protection functions and safety labels

    13

    IP54 (soundproof sets), IP56 (control system)

    14

    Water jacket preheater, oil heater are available.

    15

    Double air cleaner, spare parts, special tools are available.

    16

    Custom-made is acceptable


    Ratings and Performance Data
    Engine Brand & Model:Perkins 4016-61TRG3
    Alternator Brand & Model:Stamford PI734G
    Control System:ComAp InteliLite®MRS10
    Noise Level@7m:70.9-75.8
    Frequency & Phase:50Hz & 3 Phase
    Engine Speed: RPM1500
    Structure Type:HDP2000
    HDP2000S
    Fuel Tank Capacity: LHDP2000/
    HDP2000S/
    Fuel Consumption: l/hr (100% Load)Prime470
    Standby529
    Generator SetLength (L)Width (W)Height (H)Net Weight kg
    Modelmmmmmm
    HDP200050002200320010500
    HDP2000S122002400320032700

    Spec #1.2 Container Calculation

    Generator Set Model

    20’GP

    pcs

    40‘GP

    pcs

    40‘HQ

    pcs

    Efficiency

    HDP1500

    N/A

    N/A

    N/A

    N/A

    HDP1500S

    N/A

    N/A

    N/A

    N/A


    Spec#2 Engine Perkins 4016-61TRG3


    Spec #2.1 General Data

    Number of cylinders

    16

    Cylinder arrangement

    Vee, 60°

    Cycle

    4 stroke

    Induction system

    Turbocharged

    Combustion system

    Direct injection

    Compression ratio

    13.6:1

    Bore and Stroke

    160 x 190 mm (6.3 x 7.5 in)

    Cubic capacity

    61.123 litres

    Direction of rotation

    Anti-clockwise viewed on flywheel

    Cooling system

    Water cooled

    Total coolant capacity

    316 litres

    Total lubrication system capacity

    237.2 litres (62.7 US gals)

    Dimensions

    L4542mm

    W2185 mm

    H3175mm

    Total weight (dry)

    5570 kg

    Spec #2.2 Engine Output

    Speed

    rpm

    Run Type

    Typical Output (Net)

    Engine Power

    Gross

    Net

    kVA

    kWe

    kWm

    hp

    kWm

    hp

    1500

    Prime

    1800

    1440

    1600

    2144

    1500

    2010

    Standby

    2250

    1880

    1975

    2647

    1875

    2513

    Standby (maximum)

    2500

    2000

    2183

    2925

    2083

    2791

    *Subject to conformance with ASTM D6751 and EN14214.

    The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on typical alternator efficiencies and a power factor (cos θ) of 0.8.

    Fuel specification: BS 2869: Part 2 1998 Class A2 or ASTM D975 D2.

    Rating Definitions:

    Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours operation.

    Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.


    Spec #2.3 Fuel System

    Type of injection

    Direct

    Fuel injection pump

    Rotary

    Fuel injector opening pressure

    Multi-hole

    Delivery/hour at 1500 rpm

    23MPa

    Electronic governor (optional)

    Woodward LCG2

    Fuel lift pump

    Fuel lift pump pressure

    Electrical

    maximum suction head

    120 - 150 l/h (211 - 264 pt/m)

    maximum pressure head

    30 - 75 kPa (4.4 - 10.9 psi) a

    Fuel filter spacing

    17 kPa

    Governor type

    3.0 m

    Torque at the governor output

    Woodward LCG2

    Fuel specification

    USA Fed Off Highway - EPA2D 89.330-96

    Europe Off Highway - CEC RF-06-99

    Fuel Consumption

    Engine Speed

    1500 rpm

    1800 rpm

    UK g/hr

    l/hr

    UK g/hr

    UK g/hr

    At Standby Max power

    1.73

    7.9

    1.73

    1.73

    At Prime Power rating

    1.56

    7.1

    1.56

    1.56

    75% of prime power

    1.18

    5.4

    1.18

    1.18

    50% of prime power

    0.85

    3.9

    0.85

    0.85


    Spec #2.4 Cooling System

    Total coolant capacity

    Engine only

    73 litres

    Electropak (engine and radiator):

    -temperate

    207 litres

    -tropical

    210 litres

    Thermostat operating range

    71 - 85 °C

    Coolant temperature shutdown

    101 °C rising

    Coolant immersion heater

    4 kWe each

    Radiator

    Radiator face area

    3,46 m²

    Material and number of rows:

    -charge air and water jacket

    copper, 4 rows

    Fins per inch and material:

    -charge air and water jacket

    brass, 12 rows

    Water jacket cooling data

    Temperate and Tropical -coolant flow

    1020 litres/min

    -coolant exit temperature (max) .

    98 °C

    -coolant inlet temperature (min)

    thermostatic control

    Max permissible external system resistance

    kPa

    Thermostat operation range

    82 - 93 °C

    Max. static pressure head on pump

    30.4 kPa

    Recommended coolant

    50% anti freeze / 50% water. For complete details of recommended coolant specifications, refer to the

    Operation and Maintenance Manual for this engine model.

    Duct allowance

    Maximum additional restriction (duct allowance) to cooling airflow and resultant minimum airflow

    Ambient clearance 50% Glycol

    Duct allowance Pa

    m³/sec

    N/A

    N/A

    N/A

    N/A

    N/A

    N/A

    Spec #2.5 Induction System

    Maximum static bending moment

    at rear face of block

    1400 Nm

    Maximum air intake restriction

    -clean filter.

    2 kPa

    -dirty filter

    4 kPa

    -air filter type

    Medium duty axial flow

    Spec #2.6 Electrical System

    type

    Insulated return

    alternator

    24 volts with integral regulator

    starter motor

    24 volts

    Starter motor power

    16.4 kW

    Number of teeth on flywheel

    TBA

    Number of teeth on starter motor..

    9

    Minimum cranking speed (0°C)

    126 rpm

    Cold start recommendations

    Minimum engine cranking speed over TDC

    120 rev/min

    Minimum

    starting

    temperature

    Grade of

    engine

    lubricating

    oil

    Battery specifications

    °C

    BS3911

    Cold

    start

    amps

    SAEJ537

    Cold

    cranking

    amps

    Number

    of

    batteries

    needed

    Commercial

    ref number

    0

    20W

    540

    740

    1

    647

    -15

    10W

    540

    740

    1

    647

    -20

    5W

    600

    780

    1

    655


    Spec #2.7 Exhaust System

    Exhaust outlet size (internal)

    2 x 254 mm Table D flanges

    Back pressure for total system

    5 kPa

    Emissions statement: Constant Speed Engines for use in Industrial, IOPU and ElectropaK applications: Certified against the requirements of EU Stage IIIA (Directives 97/68/EC, as last amended, for mobile applications).


    Spec #2.8 Lubrication System

    Lubricating oil capacity


    -total system capacity

    177 litres

    -sump maximum

    157,5 litres

    -oil temperature at normal operating conditions to bearings 105 °C

    Lubricating oil pressure

    relief valve opens

    415-470 kPa

    Min oil pressure

    120 kPa

    -at maximum no-load speed

    147 kPa

    Oil flow at rated speed

    /

    Normal oil temperature

    125 °C

    Recommended SAE viscosity

    A single or multigrade oil must be used which conforms API-CH-4

    or ACEA E5.

    Spec#3 Alternator Stamford P134G

    CONTROL SYSTEM

    SEPARATELY EXCITED BY P.M.G.

    A.V.R.

    MX341

    MX321


    VOLTAGE REGULATION

    ± 1 %

    ± 0.5 %

    With 4% ENGINE GOVERNING

    SUSTAINED SHORT CIRCUIT

    REFER TO SHORT CIRCUIT DECREMENT CURVES

    INSULATION SYSTEM

    CLASS H

    PROTECTION

    IP23

    RATED POWER FACTOR

    0.8

    STATOR WINDING

    DOUBLE LAYER LAP

    WINDING PITCH

    TWO THIRDS

    WINDING LEADS

    6

    MAIN STATOR RESISTANCE

    0.0008 Ohms PER PHASE AT 22°C STAR CONNECTED

    MAIN ROTOR RESISTANCE

    2.42 Ohms at 22°C

    EXCITER STATOR RESISTANCE

    16 Ohms at 22°C

    EXCITER ROTOR RESISTANCE

    0.043 Ohms PER PHASE AT 22°C

    R.F.I. SUPPRESSION

    BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

    WAVEFORM DISTORTION

    NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%

    MAXIMUM OVERSPEED

    2250 Rev/Min

    BEARING DRIVE END

    BALL. 6232 C3

    BEARING NON-DRIVE END

    BALL. 6319 C3


    1 BEARING

    2 BEARING

    WEIGHT COMP. GENERATOR

    4054 kg

    4022 kg

    WEIGHT WOUND STATOR

    2015 kg

    2015 kg

    WEIGHT WOUND ROTOR

    1697 kg

    1654 kg

    WR² INERTIA

    52.2511 kgm2

    51.3341 kgm2

    SHIPPING WEIGHTS in a crate

    4127kg

    4091kg

    PACKING CRATE SIZE

    216 x 105 x 154(cm)

    216 x 105 x 154(cm)


    50 Hz

    60 Hz

    TELEPHONE INTERFERENCE

    THF<2%

    TIF<50

    COOLING AIR

    2.69 m³/sec 5700 cfm

    3.45 m³/sec 7300 cfm

    VOLTAGE STAR

    380/220

    400/231

    415/240

    440/254

    416/240

    440/254

    460/266

    480/277

    kVA BASE RATING FOR REACTANCE VALUES


    2135


    2200


    2200


    2160


    2475


    2640


    2695


    2750

    Xd DIR. AXIS SYNCHRONOUS

    3.71

    3.45

    3.20

    2.80

    4.48

    4.27

    3.99

    3.74

    X'd DIR. AXIS TRANSIENT

    0.21

    0.19

    0.18

    0.15

    0.25

    0.24

    0.22

    0.21

    X''d DIR. AXIS SUBTRANSIENT

    0.15

    0.14

    0.13

    0.11

    0.18

    0.17

    0.16

    0.15

    Xq QUAD. AXIS REACTANCE

    2.38

    2.22

    2.06

    Quality Cooling Type Water Cooled Perkins Diesel Generators 2000KW 4-Stroke for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Hidier Power Group (Beijing) Co., Ltd.
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0